The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4255 is a digital multimeter designed for maximum safety with voltage measurement terminals that are protected by a fuse.
DIGITAL MULTIMETER DT4255
S$ 287.80 *Pricing inclusive 9% GST
Digital Multimeter with Fuse-protected Terminals Ideal for Harsh Work Environments
Key features
• Prevents short-circuit accidents with a fast-blow fuse and current-limiting resistor (DT4255)
• Prevents accidents with clamp-on sensor-based current measurement (DT4254, DT4255)
• Voltage detection function (DT4254, DT4255)
• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
• Broad -25°C (-13°F) to 65°C (149°F) operating temperature range (DT4254, DT4255)
• Dual display lets you check voltage and frequency simultaneously
Additional information
Weight | 0.615 kg |
---|---|
Dimension | 125W×184H×62D mm |
Applications | Electrical Work |
Nos. Channel | 1 |
Safety | CAT III 1000V, CAT IV 600V |
Resistance | 60.00MΩ |
AC current range | N/A |
DC current range | N/A |
AC voltage range | 1000V |
DC voltage range | 1000V |
Specifications
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. |
---|---|
AC Voltage* range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 – 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
AUTO AC/DCV | Yes |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
DC Current range | N/A |
From 4 to 20mA Percentage conversion display | N/A |
AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 – 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Temperature (thermocouples) | N/A |
Voltage detection | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity Check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s) |
Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
Accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |
Reviews
There are no reviews yet.