The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4221 is a pocket-sized digital multimeter designed specifically for electrical work requiring optimal safety, with ±0.5% DC V accuracy and wide 40Hz to 1kHz AC V bandwidth.
DIGITAL MULTIMETER DT4221
S$ 188.60 *Pricing inclusive 9% GST
Premier Pocket DMM with CAT IV 300V/ CAT III 600V Safety
Key features
• Achieving a high level of safety in a compact body and lightweight design
• Resistance and diode testing functions omitted by design in pursuit of added safety (DT4221)
• Voltage detection function (DT4221)
• Robust design capable of withstanding a drop from a height of 1 m
• Test leads conveniently wrap around the back
• ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
• Broad -10 (14°F) to 50°C (122°F) operating temperature range
• Display backlight
Available on backorder
Additional information
Weight | 0.29 kg |
---|---|
Dimension | 95W×181H×44D mm |
Applications | Electrical Work |
Nos. Channel | 1 |
Safety | CAT III 600V, CAT IV 300V |
Resistance | 60.00MΩ |
AC voltage range | 600V |
DC voltage range | 600V |
Specifications
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
DC Voltage range | 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt |
---|---|
AC Voltage* range | 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz – 1 kHz Basic accuracy 40 – 500 Hz : ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Resistance range | N/A |
Capacitance range | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. |
Frequency range | AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges Basic accuracy: ±0.1 % rdg. ±2 dgt. |
Continuity Check | Continuity threshold [ON]: 25 Ω or less (buzzer sound), [OFF]: 245 Ω or more Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 2.5 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Voltage detection | 80 V to 600 V AC |
Other functions | Filter function, Display value hold, Relative display, Auto-power save |
Display | Main and sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s ) |
Power supply | LR03 alkaline batteries ×1, Continuous use: 40 hours (back light OFF) |
Dimensions and mass | 72 mm (2.83 in) W × 149 mm (5.87 in) H× 38 mm (1.50 in) D,190 g (6.7 oz) (with batteries and holster) |
Accessories | Test Lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×1 |